35
High Voltage Passive Probes - 10076B 100:1 Passive Probe
• Ideal for measuring up to 30 kV
• Up to 250 MHz bandwidth
• 100:1 or 1000:1 attenuation
The Agilent 10076B 4 kV 100:1 passive
probe gives you the voltage and band-
width you need for making high-voltage
measurements. Its compact design makes
it easier to probe today’s small power
electronics components and its rugged
construction means it can withstand rough
handling without breaking.
The 10076B is compatible with any
oscilloscope with 1 MΩ BNC input. For
use with the Infiniium 90000 Series scope,
use the E2697A high impedance probe
adapter. For use with the Infiniium 90000X
Series scope, use the N5449A high
impedance probe adapter.
10076B passive probe
10076B derating curve
10076B
Bandwidth 250 MHz (-3 dB)
Risetime (calculated) < 1.4 ns
Attenuation ratio 100:1
Input resistance 66.7 MΩ (when terminated into 1 MΩ)
Input capacitance Approx 3 pF
Maximum input 4000 Vpk CAT I, 1000Vpk CAT II
Compensation 6 to 20 pF range
Probe readout Yes
Cable length 1.8 m
Operating characteristics the 10076B 100:1 passive probe
Model
Number Description Quantity
10076B High-voltage probe: includes one retractable hook tip,
one-ground-bayonet, one IC probing tip, one-alligator ground
lead and a compensation screwdriver
1
10077A Accessory kit for 10076B including 1x retractable hook pin, 1x
ground lead, 1x insulation cap, 2x measuring pins and 8x ID
tags
1
Ordering information
Comentarios a estos manuales