Chapter 17 257
LTE-FDD Programming Commands
Spectrum Emissions Mask (SEM)
LTE-FDD Programming Commands
Spectrum Emissions Mask (SEM)
This section provides the remote control SCPI commands for the LTE-FDD Spectrum Emissions Mask
(SEM) measurement from within the List Sequencer. This measurement is available only if you have the
LTE-FDD measurement application licensed on the test set.
For more detailed information about the SEM measurement, refer to the online help associated with the
LTE-FDD measurement application, which is also available in PDF format (“Users and Programmers
Reference”) on the Agilent website, www.agilent.com/find/e6640a.
You can also refer to the measurement guide for the X-series LTE-FDD measurement application, which
is available on the Agilent website, www.agilent.com/find/mxa.
SEM measurement SCPI commands
There is a set of SCPI commands available to program the LTE-FDD SEM measurement when it is used
in the LTE-FDD mode. To set up the LTE-FDD measurements from within the Sequence Analyzer mode
you need to prefix the SCPI commands with LSEQuencer:LTE. For example, the [:SENSe]:SEMask
part of the SEM SCPI commands are replaced with: [:SENSe]:LSEQuencer:LTE:SEMask
The following commands are used to set up the SEM measurement.
[:SENSe]:LSEQuencer:LTE:SEMask:TYPE
[:SENSe]:LSEQuencer:LTE:SEMask:BANDwidth[1]|2:INTegration
[:SENSe]:LSEQuencer:LTE:SEMask:FREQuency[1]|2:SPAN
[:SENSe]:LSEQuencer:LTE:SEMask:BANDwidth[1]|2:[:RESolution]
[:SENSe]:LSEQuencer:LTE:SEMask:BANDwidth[1]|2:[:RESolution]:AUTO
[:SENSe]:LSEQuencer:LTE:SEMask:CARRier[:POWer]
[:SENSe]:LSEQuencer:LTE:SEMask:CARRier:AUTO[:STATe]
[:SENSe]:LSEQuencer:LTE:SEMask:CARRier:CPSD
[:SENSe]:LSEQuencer:LTE:SEMask:CARRier:PEAK[:POWer]
[:SENSe]:LSEQuencer:LTE:SEMask:OFFSet[1]|2:LIST:FREQuency:STARt
[:SENSe]:LSEQuencer:LTE:SEMask:OFFSet[1]|2:LIST:STATe
[:SENSe]:LSEQuencer:LTE:SEMask:OFFSet[1]|2:LIST:FREQuency:STOP
[:SENSe]:LSEQuencer:LTE:SEMask:OFFSet[1]|2:LIST:SIDE
[:SENSe]:LSEQuencer:LTE:SEMask:OFFSet[1]|2:LIST:BANDwidth[:RESolution]
[:SENSe]:LSEQuencer:LTE:SEMask:OFFSet[1]|2:LIST:BANDwidth[:RESolution]:AUTO
[:SENSe]:LSEQuencer:LTE:SEMask:OFFSet[1]|2:LIST:BANDwidth:IMULti
[:SENSe]:LSEQuencer:LTE:SEMask:OFFSet[1]|2:LIST:STARt:ABSolute
[:SENSe]:LSEQuencer:LTE:SEMask:OFFSet[1]|2:LIST:STOP:ABSolute