Performance Tests
E5062A Performance Test Record (for Option 175/275)
2. Performance Test
S12 or S22 (Option 275 only)
Load match 300 k - 100 M -15
Load match 100 M - 1.5 G -15
Load match 1.5 G - 3 G -15
Reflection Tracking 300 k - 100 M 1.0
Reflection Tracking 100 M - 1.5 G 1.0
Reflection Tracking 1.5 G - 3 G 1.0
Transmission
Tracking
300 k - 100 M 1.0
Transmission
Tracking
100 M - 1.5 G 1.0
Transmission
Tracking
1.5 G - 3 G 1.0
System
performance
Frequency range [Hz] Test limit [dB] Test result [dB]
System
performance
Frequency range [Hz] Test limit [dB] Test result [dB]
Directivity 300 k - 100 M -25
Directivity 100 M - 1.5 G -25
Directivity 1.5 G - 3 G -25
Source match 300 k - 100 M -25
Source match 100 M - 1.5 G -25
Source match 1.5 G - 3 G -25
Load match 300 k - 100 M -15
Load match 100 M - 1.5 G -15
Load match 1.5 G - 3 G -15
Reflection Tracking 300 k - 100 M 1.0
Reflection Tracking 100 M - 1.5 G 1.0
Reflection Tracking 1.5 G - 3 G 1.0
Transmission
Tracking
300 k - 100 M 1.0
Transmission
Tracking
100 M - 1.5 G 1.0