Agilent Technologies AGILENT U2761A Manual de servicio

Busca en linea o descarga Manual de servicio para No Agilent Technologies AGILENT U2761A. Agilent Technologies AGILENT U2761A Technical data Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 169
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente

Indice de contenidos

Pagina 1 - Waveform Generator

Agilent TechnologiesAgilent U2761AUSB ModularFunction/ArbitraryWaveform GeneratorProgrammer’s Reference

Pagina 2

1 Introduction to SCPI2 U2761A Programmer’s Reference Introduction to the SCPI Language SCPI, also known as the Standard Commands for Programmable Ins

Pagina 3 - Contents

8 Frequency Sweep Commands92 U2761A Programmer’s Reference [SOURce:]SWEep:SPACing Syntax[SOURce:]SWEep:SPACing {LINear|LOGarithmic}This command sets e

Pagina 4

Frequency Sweep Commands 8U2761A Programmer’s Reference 93[SOURce:]SWEep:TIME Syntax[SOURce:]SWEep:TIME <seconds>This command sets the number o

Pagina 5

8 Frequency Sweep Commands94 U2761A Programmer’s Reference [SOURce:]SWEep:STATe Syntax[SOURce:]SWEep:STATe {0|OFF|1|ON}This command disables or enable

Pagina 6

95Agilent U2761A USB Modular Function/Arbitrary Waveform GeneratorProgrammer’s ReferenceAgilent Technologies9

Pagina 7 - Arbitrary waveform errors 155

9 Triggering Commands96 U2761A Programmer’s Reference TRIGger[:SEQuence]:SOURce SyntaxTRIGger[:SEQuence]:SOURce {IMMediate|EXTernal|BUS|STRG}This comm

Pagina 8

Triggering Commands 9U2761A Programmer’s Reference 97ExamplesThe following command sets the trigger source to Immediate.TRIG:SOUR IMMThe following qu

Pagina 9 - Introduction to SCPI

9 Triggering Commands98 U2761A Programmer’s Reference TRIGger[:SEQuence][:IMMediate]SyntaxTRIGger[:SEQuence][:IMMediate]This command triggers a sweep

Pagina 10 - Mnemonic forms

Triggering Commands 9U2761A Programmer’s Reference 99TRIGger[:SEQuence]:SLOPe SyntaxTRIGger[:SEQuence]:SLOPe {POSitive|NEGative}This command sets the

Pagina 11 - Command separators

9 Triggering Commands100 U2761A Programmer’s Reference OUTPut:TRIGger:SLOPe SyntaxOUTPut:TRIGger:SLOPe {POSitive|NEGative}This command sets the rising

Pagina 12 - Using “?” commands

Triggering Commands 9U2761A Programmer’s Reference 101ExamplesThe following command sets the trigger slope to Positive.OUTP:TRIG:SLOP POSThe followin

Pagina 13 - Syntax conventions

Introduction to SCPI 1U2761A Programmer’s Reference 3SCPI Conventions and Data FormatsCommand separatorsUsing a colon ( : )A colon ( : ) is used to s

Pagina 14 - Parenthesis “( )”

9 Triggering Commands102 U2761A Programmer’s Reference OUTPut:TRIGger[:STATe] SyntaxOUTPut:TRIGger[:STATe] {0|OFF|1|ON}This command disables or enable

Pagina 15 - Syntax diagram conventions

103Agilent U2761A USB Modular Function/Arbitrary Waveform GeneratorProgrammer’s ReferenceAgilent Technologies10

Pagina 16 - Data types and formats

10 Arbitrary Waveform Commands104 U2761A Programmer’s Reference DATA:DAC VOLATILE SyntaxDATA:DAC VOLATILE, {<binary block>|<value>, <va

Pagina 17 - Input message terminators

Arbitrary Waveform Commands 10U2761A Programmer’s Reference 105• In the IEEE- 488.2 binary block format, a block header precedes the waveform data. T

Pagina 18 - Using device clear

10 Arbitrary Waveform Commands106 U2761A Programmer’s Reference FORMat:BORDer SyntaxFORMat:BORDer {NORMal|SWAPped}This command sets the byte order for

Pagina 19 - SCPI Status System

Arbitrary Waveform Commands 10U2761A Programmer’s Reference 107DATA:ATTRibute:AVERage? SyntaxDATA:ATTRibute:AVERage?This query returns the arithmetic

Pagina 20 - 1 Introduction to SCPI

10 Arbitrary Waveform Commands108 U2761A Programmer’s Reference DATA:ATTRibute:CFACtor? SyntaxDATA:ATTRibute:CFACtor? This query returns the crest fac

Pagina 21 - Questionable Data register

Arbitrary Waveform Commands 10U2761A Programmer’s Reference 109DATA:ATTRibute:POINts?SyntaxDATA:ATTRibute:POINts?This query returns the number of poi

Pagina 22 - Standard Event register

10 Arbitrary Waveform Commands110 U2761A Programmer’s Reference DATA:ATTRibute:PTPeak?SyntaxDATA:ATTRibute:PTPeak?This query returns the peak-to-peak

Pagina 23 - Status Byte register

111Agilent U2761A USB Modular Function/Arbitrary Waveform GeneratorProgrammer’s ReferenceAgilent Technologies11

Pagina 24

1 Introduction to SCPI4 U2761A Programmer’s Reference Use a semicolon and a colon to link commands from different subsystems. For example, in the foll

Pagina 25 - IEEE-488.2 Common Commands

11 SYSTem Commands112 U2761A Programmer’s Reference SYSTem:CDEScription?SyntaxSYSTem:CDEScription?This query identifies which slot and chassis that th

Pagina 26

SYSTem Commands 11U2761A Programmer’s Reference 113SYSTem:ERRor?SyntaxSYSTem:ERRor?This query returns the next error number and its corresponding mes

Pagina 27 - Parameter

11 SYSTem Commands114 U2761A Programmer’s Reference SYSTem:VERSion?SyntaxSYSTem:VERSion?This query returns the SCPI standard version with which the U2

Pagina 28

115Agilent U2761A USB Modular Function/Arbitrary Waveform GeneratorProgrammer’s ReferenceAgilent Technologies12Phase-Lock Commands[SOURce:]PHASe:SOUR

Pagina 29

12 Phase-Lock Commands116 U2761A Programmer’s Reference [SOURce:]PHASe:SOURceSyntax[SOURce:]PHASe:SOURce {INTernal|EXTernal|CCG}This command sets the

Pagina 30

Phase-Lock Commands 12U2761A Programmer’s Reference 117[SOURce:]PHASe[:ADJust]Syntax[SOURce:]PHASe[:ADJust] <angle>This command adjusts the pha

Pagina 31

12 Phase-Lock Commands118 U2761A Programmer’s Reference UNIT:ANGLe SyntaxUNIT:ANGLe {DEGree|RADian}This command sets either degrees or radians for the

Pagina 32

Phase-Lock Commands 12U2761A Programmer’s Reference 119[SOURce:]PHASe:REFerenceSyntax[SOURce:]PHASe:REFerenceThis command immediately sets the zero-p

Pagina 33

12 Phase-Lock Commands120 U2761A Programmer’s Reference [SOURce:]PHASe:UNLock:ERRor[:STATe]Syntax[SOURce:]PHASe:UNLock:ERRor[:STATe] {0|OFF|1|ON}This

Pagina 34

Phase-Lock Commands 12U2761A Programmer’s Reference 121OUTPut:PHASe[:STATe] SyntaxOUTPut:PHASe[:STATe] {0|OFF|1|ON}This command disables or enables t

Pagina 35

Introduction to SCPI 1U2761A Programmer’s Reference 5Using “ * ” commandsCommands starting with a “*” are called common commands. They are required t

Pagina 36

12 Phase-Lock Commands122 U2761A Programmer’s Reference

Pagina 37

123Agilent U2761A USB Modular Function/Arbitrary Waveform GeneratorProgrammer’s ReferenceAgilent Technologies13Status Reporting CommandsSTATus:PRESet

Pagina 38 - 2 IEEE-488.2 Common Commands

13 Status Reporting Commands124 U2761A Programmer’s Reference STATus:PRESetSyntaxSTATus:PRESetThis command clears all bits in the Questionable Data en

Pagina 39 - APPLy Commands

Status Reporting Commands 13U2761A Programmer’s Reference 125STATus:QUEStionable:CONDition?SyntaxSTATus:QUEStionable:CONDition? This query returns th

Pagina 40 - Using the APPLy Command

13 Status Reporting Commands126 U2761A Programmer’s Reference STATus:QUEStionable:ENABleSyntaxSTATus:QUEStionable:ENABle <value>This command ena

Pagina 41 - APPLy:SINusoid

Status Reporting Commands 13U2761A Programmer’s Reference 127ExamplesThe following command enables bit 4 (decimal value = 16) in the enable register.

Pagina 42 - APPLy:SQUare

13 Status Reporting Commands128 U2761A Programmer’s Reference STATus:QUEStionable[:EVENt]?SyntaxSTATus:QUEStionable[:EVENt]? This query returns the bi

Pagina 43 - APPLy:RAMP

129Agilent U2761A USB Modular Function/Arbitrary Waveform GeneratorProgrammer’s ReferenceAgilent Technologies14

Pagina 44 - APPLy:PULSe

14 CALibration Commands130 U2761A Programmer’s Reference CALibration:SECure:STATeSyntaxCALibration:SECure:STATe {OFF|ON|RESET}, <code>This comma

Pagina 45 - APPLy:DC

CALibration Commands 14U2761A Programmer’s Reference 131CALibration:SECure:CODE SyntaxCALibration:SECure:CODE <new code>This command inputs a n

Pagina 46 - APPLy:USER

1 Introduction to SCPI6 U2761A Programmer’s Reference Square brackets “[ ]”Some commands and parameters are enclosed in square brackets “[ ]”. Items w

Pagina 47

14 CALibration Commands132 U2761A Programmer’s Reference CALibration:SETupSyntaxCALibration:SETup <1|2|3| . . . |115>This command configures the

Pagina 48 - 3 APPLy Commands

CALibration Commands 14U2761A Programmer’s Reference 133CALibration:VALue SyntaxCALibration:VALue <value>This command specifies the measured va

Pagina 49 - Output Configuration Commands

14 CALibration Commands134 U2761A Programmer’s Reference CALibration:COUNt?SyntaxCALibration:COUNt?This query determines the number of times the U276

Pagina 50 - [SOURce:]FUNCtion[:SHAPe]

CALibration Commands 14U2761A Programmer’s Reference 135CALibration:STRing SyntaxCALibration:STRing <quoted string>This command stores a messag

Pagina 51

14 CALibration Commands136 U2761A Programmer’s Reference

Pagina 52 - SOUR : FREQ space

137Agilent U2761A USB Modular Function/Arbitrary Waveform GeneratorProgrammer’s ReferenceAgilent Technologies15

Pagina 53 - SOUR : VOLT space

15 CONFigure Command138 U2761A Programmer’s Reference CONFigure:SSISyntaxCONFigure:SSI {NONE|MASTer|SLAVe}, (@<address>[,<address>])This c

Pagina 54

CONFigure Command 15U2761A Programmer’s Reference 139ExamplesThe following example sets one U2761A unit to master and one U2761A unit to slave.For U

Pagina 55

15 CONFigure Command140 U2761A Programmer’s Reference

Pagina 56

141Agilent U2761A USB Modular Function/Arbitrary Waveform GeneratorProgrammer’s ReferenceAgilent Technologies16

Pagina 57

Introduction to SCPI 1U2761A Programmer’s Reference 7Syntax diagram conventionsFigure 1-1 Typical syntax diagramSolid lines represent the recommended

Pagina 58 - :LEV :IMM :UNIT VPP

16 Error Messages142 U2761A Programmer’s Reference Error MessagesError messages are created once an erroneous condition has been detected. • Errors ar

Pagina 59 - :SQU :DCYC percent

Error Messages 16U2761A Programmer’s Reference 143–108 Parameter not allowedMore parameters were received than were expected for the command. You may

Pagina 60 - :RAMP :SYMM percent

16 Error Messages144 U2761A Programmer’s Reference Execution errorsThe execution errors are listed in the table below.–158 String data not allowedA ch

Pagina 61 - OUTP :STAT space

Error Messages 16U2761A Programmer’s Reference 145–221 Settings conflict; frequency reduced for user functionWhen you change to the arbitrary functio

Pagina 62 - OUTP :LOAD space

16 Error Messages146 U2761A Programmer’s Reference –221 Settings conflict; pulse width increased due to large periodThe U2761A has adjusted the pulse

Pagina 63

Error Messages 16U2761A Programmer’s Reference 147–221 Settings conflict; PSK turned off by selection of other mode or modulationThe U2761A will allo

Pagina 64

16 Error Messages148 U2761A Programmer’s Reference –222 Data out of range; amplitude; value clipped to upper limitThe waveform amplitude has been limi

Pagina 65 - Pulse Configuration Commands

Error Messages 16U2761A Programmer’s Reference 149–222 Data out of range; load; value clipped to upper limitThe output load is limited to an upper bo

Pagina 66 - SOUR : PULS space

16 Error Messages150 U2761A Programmer’s Reference –222 Data out of range; FM deviation limited by maximum frequencyThe frequency deviation is limited

Pagina 67 - :PULS :HOLD WIDT

Error Messages 16U2761A Programmer’s Reference 151Device-dependent errorsThe table below contains the device-dependent errors.–222 Data out of range;

Pagina 68 - :PULS :WIDT seconds

1 Introduction to SCPI8 U2761A Programmer’s Reference Data types and formatsThe SCPI language defines different data formats for use in program messag

Pagina 69

16 Error Messages152 U2761A Programmer’s Reference Query errorsThe list of query errors is shown in the following table.Instrument errorsThe instrumen

Pagina 70 - :PULS :DCYC percent

Error Messages 16U2761A Programmer’s Reference 153Self-test errorsThe table below shows the self- test errors.Calibration errorsThe calibration error

Pagina 71 - Modulation Commands

16 Error Messages154 U2761A Programmer’s Reference 708 Calibration error; perform setting is not allowedThe calibration setting was predetermined by c

Pagina 72 - [SOURce:]AM:INTernal:FUNCtion

Error Messages 16U2761A Programmer’s Reference 155Arbitrary waveform errorsThe table below shows the Arbitrary waveform errors.Tabl e 16-8 Arbitrary

Pagina 73

16 Error Messages156 U2761A Programmer’s Reference

Pagina 74 - SOUR : AM space

157Agilent U2761A USB Modular Function/Arbitrary Waveform GeneratorProgrammer’s ReferenceAgilent Technologies17

Pagina 75

17 Factory Default Settings158 U2761A Programmer’s Reference The factory default settings in the following table are used when the U2761A is powered o

Pagina 76

Factory Default Settings 17U2761A Programmer’s Reference 159FM deviation 100 HzPM deviation 180 °Modulation state OffShift keying modulationCarrier w

Pagina 77 - [SOURce:]FM:INTernal:FUNCtion

17 Factory Default Settings160 U2761A Programmer’s Reference Phase output state OffCalibrationCalibration security state OnCalibration security code U

Pagina 78

© Agilent Technologies, Inc. 2008–2013Third Edition, January 18, 2013U2761-90011www.agilent.comAgilent TechnologiesContact usTo obtain service, warran

Pagina 79 - SOUR : FM space

Introduction to SCPI 1U2761A Programmer’s Reference 9StringParameters that contain virtually any set of ASCII characters. A string must begin and end

Pagina 80

1 Introduction to SCPI10 U2761A Programmer’s Reference Using device clearDevice clear is an IEEE- 488 low- level bus message that you can use to retur

Pagina 81

Introduction to SCPI 1U2761A Programmer’s Reference 11SCPI Status SystemThe status system records various instrument conditions and states in several

Pagina 82

ii U2761A Programmer’s Reference Notices© Agilent Technologies, Inc. 2008–2013No part of this manual may be reproduced in any form or by any means (in

Pagina 83

1 Introduction to SCPI12 U2761A Programmer’s Reference Figure 1-2 Status system diagram

Pagina 84 - SOUR : PM space

Introduction to SCPI 1U2761A Programmer’s Reference 13Questionable Data registerThe Questionable Data register group provides the information on the

Pagina 85

1 Introduction to SCPI14 U2761A Programmer’s Reference Standard Event registerThe Standard Event register group reports the following types of instrum

Pagina 86

Introduction to SCPI 1U2761A Programmer’s Reference 15Status Byte registerThe Status Byte register group reports the conditions from the other status

Pagina 87 - Shift Keying Commands

1 Introduction to SCPI16 U2761A Programmer’s Reference

Pagina 88 - SOUR : ASK space

17Agilent U2761A USB Modular Function/Arbitrary Waveform GeneratorProgrammer’s ReferenceAgilent Technologies2

Pagina 89

2 IEEE-488.2 Common Commands18 U2761A Programmer’s Reference *CLSSyntax*CLSThis command is used to clear the event registers in all register groups, a

Pagina 90 - SOUR : FSK space

IEEE-488.2 Common Commands 2U2761A Programmer’s Reference 19*ESESyntax*ESE <value>This command sets the bits in the Standard Event enable regis

Pagina 91

2 IEEE-488.2 Common Commands20 U2761A Programmer’s Reference *ESR?Syntax*ESR?This query reads the event register of the Standard Event register group

Pagina 92

IEEE-488.2 Common Commands 2U2761A Programmer’s Reference 21*IDN?Syntax*IDN?This query reads the U2761A identification string which contains four com

Pagina 93 - SOUR : PSK space

U2761A Programmer’s Reference iiiContents1 Introduction to SCPI 1Introduction to the SCPI Language 2SCPI Conventions and Data Formats 3Command separa

Pagina 94

2 IEEE-488.2 Common Commands22 U2761A Programmer’s Reference *OPCSyntax*OPC This command sets the “Operation Complete” bit (bit 0) in the Standard Eve

Pagina 95

IEEE-488.2 Common Commands 2U2761A Programmer’s Reference 23*RSTSyntax*RSTThis command resets the U2761A to its factory default state, which is the s

Pagina 96 - 7 Shift Keying Commands

2 IEEE-488.2 Common Commands24 U2761A Programmer’s Reference *SRESyntax*SRE <value>This command enables the bits in the Status Byte enable regis

Pagina 97 - Frequency Sweep Commands

IEEE-488.2 Common Commands 2U2761A Programmer’s Reference 25The following query returns the bit enabled in the register.*SRE?Typical response: +16

Pagina 98

2 IEEE-488.2 Common Commands26 U2761A Programmer’s Reference *STB?Syntax*STB?This query reads the summary (condition) of the Status Byte register and

Pagina 99

IEEE-488.2 Common Commands 2U2761A Programmer’s Reference 27*TRGSyntax*TRGThis command triggers a sweep from the remote interface only if the bus (so

Pagina 100 - :SPAC LIN

2 IEEE-488.2 Common Commands28 U2761A Programmer’s Reference *TST?Syntax*TST?This query performs a self-test on the U2761A and returns +0 (pass) or +1

Pagina 101

IEEE-488.2 Common Commands 2U2761A Programmer’s Reference 29*WAISyntax*WAIThis command sets the U2761A to wait for the completion of all pending oper

Pagina 102

2 IEEE-488.2 Common Commands30 U2761A Programmer’s Reference

Pagina 103 - Triggering Commands

31Agilent U2761A USB Modular Function/Arbitrary Waveform GeneratorProgrammer’s ReferenceAgilent Technologies3

Pagina 104 - TRIG :SEQ space:SOUR IMM

iv U2761A Programmer’s Reference APPLy:DC 37APPLy:USER 38APPLy? 394 Output Configuration Commands 41[SOURce:]FUNCtion[:SHAPe] 42[SOURce:]FREQuency 44[

Pagina 105 - Examples

3 APPLy Commands32 U2761A Programmer’s Reference Using the APPLy CommandThe APPLy command provides the most straightforward method to program the U276

Pagina 106 - TRIG :SEQ :IMM

APPLy Commands 3U2761A Programmer’s Reference 33APPLy:SINusoidSyntaxAPPLy:SINusoid [<frequency> [,<amplitude> [,<offset>] ]]This co

Pagina 107 - TRIG :SEQ space:SLOP POS

3 APPLy Commands34 U2761A Programmer’s Reference APPLy:SQUareSyntaxAPPLy:SQUare [<frequency> [,<amplitude> [,<offset>] ]]This comman

Pagina 108 - OUTP :TRIG space:SLOP POS

APPLy Commands 3U2761A Programmer’s Reference 35APPLy:RAMPSyntaxAPPLy:RAMP [<frequency> [,<amplitude> [,<offset>] ]]This command ou

Pagina 109

3 APPLy Commands36 U2761A Programmer’s Reference APPLy:PULSeSyntaxAPPLy:PULSe [<frequency> [,<amplitude> [,<offset>] ]]This command

Pagina 110 - OUTP :TRIG space

APPLy Commands 3U2761A Programmer’s Reference 37APPLy:DCSyntaxAPPLy:DC [<frequency|DEFault> [,<amplitude>|DEFault> [,<offset>] ]

Pagina 111 - Arbitrary Waveform Commands

3 APPLy Commands38 U2761A Programmer’s Reference APPLy:USERSyntaxAPPLy:USER [<frequency> [,<amplitude> [,<offset>] ]]This command ou

Pagina 112 - DATA:DAC VOLATILE

APPLy Commands 3U2761A Programmer’s Reference 39APPLy?SyntaxAPPLy?This query returns the U2761A current configuration of the function, frequency, amp

Pagina 113

3 APPLy Commands40 U2761A Programmer’s Reference

Pagina 114 - :BORD NORM

41Agilent U2761A USB Modular Function/Arbitrary Waveform GeneratorProgrammer’s ReferenceAgilent Technologies4

Pagina 115 - DATA:ATTRibute:AVERage?

U2761A Programmer’s Reference v[SOURce:]PM:DEViation 77[SOURce:]PM:STATe 787 Shift Keying Commands 79[SOURce:]ASKey:INTernal:RATE 80[SOURce:]ASKey:ST

Pagina 116 - DATA:ATTRibute:CFACtor?

4 Output Configuration Commands42 U2761A Programmer’s Reference [SOURce:]FUNCtion[:SHAPe]Syntax[SOURce:]FUNCtion[:SHAPe] {SINusoid|SQUare|RAMP|PULSe|D

Pagina 117 - DATA :ATTR :POIN ?

Output Configuration Commands 4U2761A Programmer’s Reference 43ExamplesThe following command sets the output function to Square.FUNC SQUThe following

Pagina 118 - DATA:ATTRibute:PTPeak?

4 Output Configuration Commands44 U2761A Programmer’s Reference [SOURce:]FREQuency Syntax[SOURce:]FREQuency <frequency>This command sets the out

Pagina 119 - SYSTem Commands

Output Configuration Commands 4U2761A Programmer’s Reference 45[SOURce:]VOLTage[:LEVel][:IMMediate][:AMPLitude]Syntax[SOURce:]VOLTage[:LEVel][:IMMedi

Pagina 120 - SYSTem:CDEScription?

4 Output Configuration Commands46 U2761A Programmer’s Reference ExamplesThe following command sets the output amplitude to 5 Vpp.VOLT 5 VPPThe followi

Pagina 121 - SYSTem:ERRor?

Output Configuration Commands 4U2761A Programmer’s Reference 47[SOURce:]VOLTage[:LEVel][:IMMediate]:OFFSetSyntax[SOURce:]VOLTage[:LEVel][:IMMediate]:

Pagina 122 - SYSTem:VERSion?

4 Output Configuration Commands48 U2761A Programmer’s Reference [SOURce:]VOLTage[:LEVel][:IMMediate]:HIGHSyntax[SOURce:]VOLTage[:LEVel][:IMMediate]:HI

Pagina 123 - Phase-Lock Commands

Output Configuration Commands 4U2761A Programmer’s Reference 49[SOURce:]VOLTage[:LEVel][:IMMediate]:LOWSyntax[SOURce:]VOLTage[:LEVel][:IMMediate]:LOW

Pagina 124 - SOUR : PHAS space:SOUR INT

4 Output Configuration Commands50 U2761A Programmer’s Reference [SOURce:]VOLTage[:LEVel][:IMMediate]:UNITSyntax[SOURce:]VOLTage[:LEVel][:IMMediate]:UN

Pagina 125 - SOUR : PHAS space

Output Configuration Commands 4U2761A Programmer’s Reference 51[SOURce:]FUNCtion:SQUare:DCYCle Syntax[SOURce:]FUNCtion:SQUare:DCYCle <percent>T

Pagina 126 - :ANGL DEG

vi U2761A Programmer’s Reference 11 SYSTem Commands 111SYSTem:CDEScription? 112SYSTem:ERRor? 113SYSTem:VERSion? 11412 Phase-Lock Commands 115[SOURce:]

Pagina 127 - SOUR : PHAS :REF

4 Output Configuration Commands52 U2761A Programmer’s Reference [SOURce:]FUNCtion:RAMP:SYMMetrySyntax[SOURce:]FUNCtion:RAMP:SYMMetry <percent>Th

Pagina 128 - :UNL :ERR :STAT

Output Configuration Commands 4U2761A Programmer’s Reference 53OUTPut[:STATe]SyntaxOUTPut[:STATe] {0|OFF|1|ON}This command disables or enables the U2

Pagina 129 - OUTP :PHAS space

4 Output Configuration Commands54 U2761A Programmer’s Reference OUTPut:LOAD SyntaxOUTPut:LOAD {<ohms>|INFinity}This command specifies the desire

Pagina 130 - 12 Phase-Lock Commands

Output Configuration Commands 4U2761A Programmer’s Reference 55ExamplesThe following command specifies the output termination value as 2 kΩ.OUTP:LOAD

Pagina 131 - Status Reporting Commands

4 Output Configuration Commands56 U2761A Programmer’s Reference

Pagina 132 - STATus:PRESet

57Agilent U2761A USB Modular Function/Arbitrary Waveform GeneratorProgrammer’s ReferenceAgilent Technologies5Pulse Configuration Commands[SOURce:]PUL

Pagina 133 - STAT ?:QUES :COND

5 Pulse Configuration Commands58 U2761A Programmer’s Reference [SOURce:]PULSe:PERiod Syntax[SOURce:]PULSe:PERiod <seconds>This command sets the

Pagina 134 - STATus:QUEStionable:ENABle

Pulse Configuration Commands 5U2761A Programmer’s Reference 59[SOURce:]FUNCtion:PULSe:HOLDSyntax[SOURce:]FUNCtion:PULSe:HOLD {WIDTh|DCYCle}This comma

Pagina 135

5 Pulse Configuration Commands60 U2761A Programmer’s Reference [SOURce:]FUNCtion:PULSe:WIDTh Syntax[SOURce:]FUNCtion:PULSe:WIDTh <seconds>This c

Pagina 136 - STAT :QUES ?:EVEN

Pulse Configuration Commands 5U2761A Programmer’s Reference 61The following query returns the pulse width.FUNC:PULS:WIDT?Typical response: +2.0000000

Pagina 137 - CALibration Commands

U2761A Programmer’s Reference viiInstrument errors 152Self-test errors 153Calibration errors 153Arbitrary waveform errors 15517 Factory Default Setti

Pagina 138 - :STAT , code

5 Pulse Configuration Commands62 U2761A Programmer’s Reference [SOURce:]FUNCtion:PULSe:DCYCleSyntax[SOURce:]FUNCtion:PULSe:DCYCle <percent>This

Pagina 139 - CAL space:SEC :CODE new code

63Agilent U2761A USB Modular Function/Arbitrary Waveform GeneratorProgrammer’s ReferenceAgilent Technologies6

Pagina 140 - CALibration:SETup

6 Modulation Commands64 U2761A Programmer’s Reference [SOURce:]AM:INTernal:FUNCtionSyntax[SOURce:]AM:INTernal:FUNCtion {SINusoid|SQUare|RAMP|NRAMp|TRI

Pagina 141 - CAL space

Modulation Commands 6U2761A Programmer’s Reference 65ExamplesThe following command sets the modulating waveform to Sine.AM:INT:FUNC SINThe following

Pagina 142 - CAL :COUN ?

6 Modulation Commands66 U2761A Programmer’s Reference [SOURce:]AM:INTernal:FREQuencySyntax[SOURce:]AM:INTernal:FREQuency <frequency>This command

Pagina 143

Modulation Commands 6U2761A Programmer’s Reference 67[SOURce:]AM:DEPThSyntax[SOURce:]AM:DEPTh <depth in percent>This command sets the amplitude

Pagina 144 - 14 CALibration Commands

6 Modulation Commands68 U2761A Programmer’s Reference [SOURce:]AM:STATe Syntax[SOURce:]AM:STATe {0|OFF|1|ON}This command disables or enables the ampli

Pagina 145 - CONFigure Command

Modulation Commands 6U2761A Programmer’s Reference 69[SOURce:]FM:INTernal:FUNCtionSyntax[SOURce:]FM:INTernal:FUNCtion {SINusoid|SQUare|RAMP|NRAMp|TRI

Pagina 146 - :SSI , @address , address( )

6 Modulation Commands70 U2761A Programmer’s Reference ExamplesThe following command sets the modulating waveform to Sine.FM:INT:FUNC SINThe following

Pagina 147

Modulation Commands 6U2761A Programmer’s Reference 71[SOURce:]FM:INTernal:FREQuency Syntax[SOURce:]FM:INTernal:FREQuency <frequency>This comman

Pagina 148 - 15 CONFigure Command

viii U2761A Programmer’s Reference

Pagina 149 - Error Messages

6 Modulation Commands72 U2761A Programmer’s Reference [SOURce:]FM:DEViation Syntax[SOURce:]FM:DEViation <peak deviation in Hz>This command sets

Pagina 150

Modulation Commands 6U2761A Programmer’s Reference 73[SOURce:]FM:STATe Syntax[SOURce:]FM:STATe {0|OFF|1|ON}This command disables or enables the frequ

Pagina 151 - Error Messages 16

6 Modulation Commands74 U2761A Programmer’s Reference [SOURce:]PM:INTernal:FUNCtion Syntax[SOURce:]PM:INTernal:FUNCtion {SINusoid|SQUare|RAMP|NRAMp|TR

Pagina 152 - Execution errors

Modulation Commands 6U2761A Programmer’s Reference 75ExamplesThe following command sets the modulating waveform to Sine.PM:INT:FUNC SINThe following

Pagina 153

6 Modulation Commands76 U2761A Programmer’s Reference [SOURce:]PM:INTernal:FREQuencySyntax[SOURce:]PM:INTernal:FREQuency <frequency>This command

Pagina 154 - 16 Error Messages

Modulation Commands 6U2761A Programmer’s Reference 77[SOURce:]PM:DEViation Syntax[SOURce:]PM:DEViation <deviation in degrees>This command sets

Pagina 155

6 Modulation Commands78 U2761A Programmer’s Reference [SOURce:]PM:STATeSyntax[SOURce:]PM:STATe {0|OFF|1|ON}This command disables or enables the phase

Pagina 156

79Agilent U2761A USB Modular Function/Arbitrary Waveform GeneratorProgrammer’s ReferenceAgilent Technologies7

Pagina 157

7 Shift Keying Commands80 U2761A Programmer’s Reference [SOURce:]ASKey:INTernal:RATESyntax[SOURce:]ASKey:INTernal:RATE <rate in Hz>This command

Pagina 158

Shift Keying Commands 7U2761A Programmer’s Reference 81[SOURce:]ASKey:STATeSyntax[SOURce:]ASKey:STATe {0|OFF|1|ON}This command disables or enables th

Pagina 159 - Device-dependent errors

1Agilent U2761A USB Modular Function/Arbitrary Waveform GeneratorProgrammer’s ReferenceAgilent Technologies1

Pagina 160 - Instrument errors

7 Shift Keying Commands82 U2761A Programmer’s Reference [SOURce:]FSKey:FREQuency Syntax[SOURce:]FSKey:FREQuency <frequency>This command sets the

Pagina 161 - Calibration errors

Shift Keying Commands 7U2761A Programmer’s Reference 83[SOURce:]FSKey:INTernal:RATESyntax[SOURce:]FSKey:INTernal:RATE <rate in Hz>The command s

Pagina 162

7 Shift Keying Commands84 U2761A Programmer’s Reference [SOURce:]FSKey:STATe Syntax[SOURce:]FSKey:STATe {0|OFF|1|ON}This command disables or enables t

Pagina 163 - Arbitrary waveform errors

Shift Keying Commands 7U2761A Programmer’s Reference 85[SOURce:]PSKey:DEViation Syntax[SOURce:]PSKey:DEViation <deviation in degrees>This comma

Pagina 164

7 Shift Keying Commands86 U2761A Programmer’s Reference [SOURce:]PSKey:INTernal:RATE Syntax[SOURce:]PSKey:INTernal:RATE <rate in Hz>This command

Pagina 165 - Factory Default Settings

Shift Keying Commands 7U2761A Programmer’s Reference 87[SOURce:]PSKey:STATeSyntax[SOURce:]PSKey:STATe {0|OFF|1|ON}This command disables or enables th

Pagina 166

7 Shift Keying Commands88 U2761A Programmer’s Reference

Pagina 167 - Factory Default Settings 17

89Agilent U2761A USB Modular Function/Arbitrary Waveform GeneratorProgrammer’s ReferenceAgilent Technologies8

Pagina 168 - 17 Factory Default Settings

8 Frequency Sweep Commands90 U2761A Programmer’s Reference [SOURce:]FREQuency:STARtSyntax[SOURce:]FREQuency:STARt <frequency>This command sets t

Pagina 169 - Agilent Technologies

Frequency Sweep Commands 8U2761A Programmer’s Reference 91[SOURce:]FREQuency:STOP Syntax[SOURce:]FREQuency:STOP <frequency>This command sets th