544 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide
5 Commands by Subsystem
:TRIGger:M1553:SOURce:LOWer
(see page 750)
Command Syntax
:TRIGger:M1553:SOURce:LOWer <source>
<source> ::= {CHANnel<n>}
<n> ::= {2 | 4}
The :TRIGger:M1553:SOURce:LOWer command controls which signal is used
as the Lower Threshold Channel source by the serial decoder and/or
trigger when in MIL- 1553 mode.
Query Syntax
:TRIGger:M1553:SOURce:LOWer?
The :TRIGger:M1553:SOURce:LOWer? query returns the currently set Lower
Threshold Channel source.
Return Format
<source><NL>
<source> ::= {CHAN<n>}
<n> ::= {2 | 4}
See Also "Introduction to :TRIGger Commands" on page 440
":TRIGger:MODE" on page 447
":TRIGger:M1553:SOURce:UPPer" on page 545