Commands by Subsystem 5
Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 487
:TRIGger:FLEXray:FRAMe:CCRepetition
(see page 750)
Command Syntax
:TRIGger:FLEXray:FRAMe:CCRepetition <cycle_count_repetition>
<cycle_count_repetition> ::= {ALL | <rep #>}
<rep #> ::= integer from 2-64
The :TRIGger:FLEXray:FRAMe:CCRepetition command sets the repetition
number of the FlexRay cycle count (in the frame header) to trigger on. The
cycle count repetition setting is only valid when the FlexRay trigger mode
is set to FRAME.
Query Syntax
:TRIGger:FLEXray:FRAMe:CCRepetition?
The :TRIGger:FLEXray:FRAMe:CCRepetition? query returns the current
cycle count repetition setting for the FlexRay frame trigger setup.
Return Format
<cycle_count_repetition><NL>
<cycle_count_repetition> ::= {ALL | <rep #>}
<rep #> ::= integer from 2-64
See Also "Introduction to :TRIGger Commands" on page 440
":TRIGger:FLEXray:TRIGger" on page 491
NOTE
This command is only valid when the FLEXray triggering and serial decode option (Option