Agilent Technologies 8922M Guía de usuario Pagina 144

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 384
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 143
9-18
Cell Control Subsystem
CALL:TCHControl
CALL:TCHControl
Description Sets/queries the TCH Control selection.
Syntax CELL:CALL:TCHControl?
CELL:CALL:TCHControl <string>
Options ’TCH1 HO’ | ’TCH2 HO’ |
’TCH1 ASGN’ | ’TCH2 ASGN’
Where;
TCH1 HO means upon execution, cause an intracell HandOver to TCH1 based on the
CELL:TCH1 selections.
TCH2 HO means upon execution, cause an intracell HandOver to TCH2. based on the
CELL:TCH2 selections.
TCH1 ASGN means upon execution, do a traffic channel assignment based on the
CELL:TCH1 selections.
TCH2 ASGN means upon execution, do a traffic channel assignment based on the
CELL:TCH2 selections.
CALL:TCHControl:EXECute
Description EXECutes the TCH Control selection.
Syntax CELL:CALL:TCHControl:EXECute
Options Not Applicable.
MODE
Description Selects/queries the Operating Mode of Agilent 8922M/S.
Syntax CELL:MODE?
CELL:MODE <string>
Options ’ACTIVE CELL’ | ’TEST MODE’ |
’CW GENERATOR’ | ’ACTIVE CELL +’ |
’TEST MODE +’ | ’CW GENERATOR +’
Vista de pagina 143
1 2 ... 139 140 141 142 143 144 145 146 147 148 149 ... 383 384

Comentarios a estos manuales

Sin comentarios