32-6
RF Analyzer Subsystem
FREQuency
FREQuency
Description Sets/queries the non-hop FREQuency for the RF ANalyzer.
Default GPIB unit is HZ.
Default display unit is MHZ.
Syntax RFANalyzer:FREQuency?
RFANalyzer:FREQuency <real> | [:FNUM]
Options Refer to Appendix B.
FREQuency:GTIMe
Description Sets/queries the RF ANalyzer Gate TIME (RF Cnt Gate).
Default GPIB unit is seconds (S).
Default display unit is micro-seconds (us).
Syntax RFANalyzer:FREQuency:GTIMe?
RFANalyzer:FREQuency:GTIMe <real> | [:INUM]
Options Refer to Appendix A.
FREQuency:HMEas
Description Sets the Hop Meas Frequency, which is the frequency to be assumed when making
measurements while hopping.
Default GPIB unit is HZ.
Default display unit is MHZ.
Syntax RFANalyzer:FREQuency:HMEas <real> | [:FNUM]
Options Refer to Appendix B.