Screen Reference 5
N9360A Multi UE Tester GSM User Manual 5-35
Softkey Menu 3
Simple: Displays a Pass/Fail result of whole measurement in
the middle of the measurement result field in zoom.
Detail: Displays a Pass/Fail result at each item cell in the
measurement result field.
Value: Displays a measurement value at each item cell in the
measurement result field.
Cancel: Cancels changing the display mode and returns to the
softkey menu 1.
Screen Field
Set the input fields in the screen field according to the following
description of Table 5-7 to execute a new test.
Table 5-7 [Automatic Test: Stand-by] Summary Screen Input Field
Input Field Description
Procedure Displays a list of parameter file names stored in the Tester.
Select a file to recall for a test.
If the Tester is using a parameter file, the file name is displayed in this field. If the Tester contains
parameter files, a list of those filename is displayed in this field for selection.
BCCH
*
Sets the broadcast control channel number.
The allowable range is as follows:
GSM850: 128 to 251
GSM900: 0 to 124 and 955 to 1023
DCS1800: 512 to 885
PCS1900: 512 to 810
TCH (Talk)
*
Sets a traffic channel number for Talk tests.
The allowable range is as follows:
GSM850: 128 to 251
GSM900: 0 to 124 and 955 to 1023
DCS1800: 512 to 885
PCS1900: 512 to 810
TCH
*
Sets up to the six traffic channels number for RF tests. The allowable range is as follows:
GSM850: 128 to 251
GSM900: 0 to 124 and 955 to 1023
DCS1800: 512 to 885
PCS1900: 512 to 810
* The changing magnification softkey is available. Refer to Storing Numeric Values on page 8 and Changing Magnification Softkey on