Agilent Technologies N9360A Manual de usuario Pagina 189

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 354
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 188
Screen Reference 5
N9360A Multi UE Tester GSM User Manual 5-71
Spectrum Monitor
The RF spectrum of the traffic channel can be measured by
Spectrum Monitor.
The spectrum, which is measured from f
c
to f
c
+ 400 kHz relative
to the traffic channel frequency, is shown with readouts at
+200kHz (M1) and +250kHz (M2) offsets.
Table 5-23 [Manual Test] GSM Mode Sensitivity/RX Quality/RX Level Screen Field
Screen Field Description
BER (Class Ib)
(Test Loop A)
Measured BER and the HI Limit are shown. The HI Limit is set on the [Configuration: Test Condition]
screen.
BER (Class II)
(Test Loop A)
Measured BER and the HI Limit are shown. The HI Limit is set on the [Configuration: Test Condition]
screen.
FER
(Test Loop A)
Measured FER and the HI Limit are shown. The HI Limit is set on the [Configuration: Test Condition]
screen.
Fast BER
(Test Loop C)
Measured Fast BER and the HI Limit are shown. The HI Limit is set on the [Configuration: Test
Condition] screen.
RX Quality RX Quality measured with the mobile phone, the HI and the LO Limit are shown. The HI and the LO
Limit are set on the [Configuration: Test Condition] screen.
RX Level RX Level measured with the mobile phone, the HI and the LO Limit are shown. The HI and the LO
Limit are set on the [Configuration: Test Condition] screen.
Vista de pagina 188
1 2 ... 184 185 186 187 188 189 190 191 192 193 194 ... 353 354

Comentarios a estos manuales

Sin comentarios