Agilent Technologies DP235 Guía de usuario Pagina 440

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 628
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 439
440
Specifications
General Information
Specifications (logic analyzer)
The specifications are the performance standards against which the
product is tested. Refer to the Agilent Technologies 1670G Logic
Analyzers Service Guide (available from your Agilent Technologies
Sales Office) for testing procedures.
Maximum state speed 150 MHz
Minimum state clock pulse width
*
3.5 ns
Minimum master to master clock time
*
6.66 ns
Minimum glitch width
*
3.5 ns
Setup/Hold time:
*
Single clock, single edges 3.0/0.0 ns through -0.5/3.5 ns,
adjustable in 500-ps increments
Single clock, multiple edges 3.5/0.0 ns through -0.5/4.0 ns,
adjustable in 500-ps increments
Multiple clocks, multiple edges 4.0/0.0 ns through -0.5/4.5 ns,
adjustable in 500-ps increments
*Specified for an input signal VH = -0.9 V, VL = -1.7 V, slew rate = 1 V/ns,
and threshold = -1.3 V.
Vista de pagina 439
1 2 ... 435 436 437 438 439 440 441 442 443 444 445 ... 627 628

Comentarios a estos manuales

Sin comentarios