DisplayPort Test Implementation Group 12 Agilent J-BERT N4903B & 90000A/X/Q Series Sink Draft2
fine-tuned by using a channel with more loss and applied de-emphasis, see E appendix.
Note: The above table is an example of a HW setup that provides adequate ISI for the
setup used during development of this MOI. The actual ISI calibration results may vary
depending on J20, cables and adapters used. It is up to the user to ensure that the ISI
values in the PHY CTS 1.2b for ISI are achieved and measured. You should make sure to
capture the screenshot of the ISI you calibrate to and keep it with your test results for
future reference. It is not required to use the J20 module. Any other combination of ISI
traces and/or cables can be used as long as the ISI is within target limits.
2. Using the test pattern (PRBS7 for HBR CP2520 for HBR2), verify that the ISI measured at TP3_EQ
is equal to the ISI value in Table 4-3 of the PHY1.2B CTS for HBR and Table 4-4 of the PHY1.2B
CTS for HBR2. The JMD’s clock recovery shall be set to the second order clock recovery function
described in Section 2.1 for this step. For RBR, use PRBS7 and calibrate ISI at TP3 without
equalizer.
For RBR
For HBR
For HBR2
In the J-BERT N4903B PG > Bit
Rate Setup Menu:
Select 1.620 Gb/s (DP-RBR)
In Pattern > Select Menu
Select 2^n 1, and Select 2^7-1
(PRBS7)
In PG Data Output Menu:
Set V
ampl
to 1V
diff
Turn on the PG Data Outputs
See C appendix for detailed
procedure.
Repeat measurement at least 5
times and average the results.
Verify ISI to be 570mUI +/-5%.
In the J-BERT N4903B PG > Bit
Rate Setup Menu:
Select 2.7 Gb/s (DP-HBR)
In Pattern > Select Menu
Select 2^n 1, and Select 2^7-1
(PRBS7)
In PG Data Output Menu:
Set V
ampl
to 600mV
diff
Turn on the PG Data Outputs
Use Equalizer, Serial Data and
EZJIT wizards to make ISI
measurement on oscilloscope.
See Appendix B for detailed
procedure.
Repeat measurement at least 5
times and average the results.
Verify ISI to be 161mUI +/-5%.
In the J-BERT N4903B PG >
Bit Rate Setup Menu:
Select 5.4 Gb/s (DP- HBR2)
In Pattern > Select Menu
Select User Pattern from File.
Select Browse
Select Pattern
C:\N4903B\Pattern\Demo
\DisplayPort\HBR2_SR-CP-
CP-
SR248_CompEyePattern.ptrn
(AKA CP2520)
Press OK
Press Apply
Press OK
In PG Data Output Menu:
Set V
ampl
to 1V
diff
Turn on the PG Data Outputs
Use Equalizer, Serial Data and
EZJIT wizards to make ISI
measurement on oscilloscope.
See Appendix B for detailed
procedure.
Repeat measurement at least 5
times and average the results.