DisplayPort Test Implementation Group 5 Agilent J-BERT N4903B & 90000A/X/Q Series Sink Draft2
2 INTRODUCTION
These Methods of Implementations describe the step-by-step calibration and procedures to perform DP
1.2b sink tests of the VESA DisplayPort Logo Compliance Program using the Agilent J-BERTN4903B
and DSA90000A/X/Q Series Oscilloscopes. Other Stressed Signal Generators can be used as long as
below calibration procedures can be performed. This procedure is in conformance with the PHY
Compliance Test Specification (CTS) 1.2b. Sink tests are required to qualify a Sink product or silicon
building block for Logo certification and listing on the DP Integrators List.
Formally, each test description in the CTS contains the following sections:
Test Objective
Interoperability statement
Test conditions
Measurement requirements and
Pass/fail criteria
This MOI reduces the CTS test description to practice using the specified test equipment and procedures
in an effort to standardize testing across ATCs and equipment manufacturers who perform their own
certification measurements.