Chapter 1 221
GPIB Command Dictionary
MEASure subsystem
:CANalyzer:ERRor:PHASe <meas cmnd>
:CANalyzer:ERRor:PHASe?
These commands set/query the phase error measurement.
This measurement utilizes the Number Measurement Syntax, but does
not use the :METer command.
Syntax
MEAS:CAN:ERR:PHAS <meas cmd>
!See “Number Measurement Syntax” on page 283.
MEAS:CAN:ERR:PHAS?
Example
MEAS:CAN:ERR:PHAS?
Screen/field equivalent
MEAS:CAN:ERR:PHAS? reads the Phase Error measurement field on
the CDMA ANALYZER screen. This measurement is also displayed on
the CDMA GENERATOR screen.
:CANalyzer:EVM <meas cmnd>
:CANalyzer:EVM?
These commands set/query the error vector magnitude (EVM)
measurement.
This measurement utilizes the Number Measurement Syntax, but does
not use the :METer command.
Syntax
MEAS:CAN:EVM <meas cmd>
!See “Number Measurement Syntax” on page 283.
MEAS:CAN:EVM?
Example
MEAS:CAN:EVM? !returns EVM in %
Screen/field equivalent
MEAS:CAN:EVM? reads the EVM measurement field on the CDMA
ANALYZER screen. This measurement is also displayed on the CDMA
GENERATOR screen.