© Agilent Technologies2000–2003 Agilent 3070 / 79000 DUT Power Supply Installation 22
Installing DUT Power Supplies
Installing DUT
Power Supplies
This section contains:
Introduction, 22
Installing the DUT Power Supply in a 307X System, 23
Installing the DUT Power Supply in a 317X System, 24
Installing the DUT Power Supply in a 327X System, 30
Installing the DUT Power Supplies in a 79000 System,
35
Introduction
This section describes how to install the DUT power
supply in the module or support bay. Proceed to the
section with instructions for a particular 3070 System.
To identify which model of system you are working on,
read the Common Testhead Product Number, which is
printed on the serial number label on the rear of the
cradle. Refer to Table 7 to relate the Common Testhead
product number to a model number.
The 79000 Functional Test System does not have a
common testhead number.
In the 307X, 317X and 327X systems, you must install a
radiation shield along with the DUT power supply. The
79000 system does not require the radiation shield.
When installing a high-voltage 6634A/B DUT power
supply in a 317X, you must install the shield
E4034-00601, shown in Figure 7 on page 23. When
installing a Faceless 6624A or a high-voltage 6634A/B
in a 327X, you must install the shield E3770-00601
(also shown in Figure 8 on page 25) unless one is
already installed.
Table 7 Common testhead product numbers
System Model Series I Testhead Series II Testhead Series III Testhead
307X (4-module Testhead) E1171A E4026A E9900A
317X (2-module Testhead) E1170A E4025A E9998A
327X (1-module Testhead) N/A E3770A E9997A