© Agilent Technologies2000–2003 Agilent 3070 / 79000 DUT Power Supply Installation 55
Connecting the DUT Power Supply Cables
6634A/B (E4034A) Supply
The 6634A/B DUT Power Supply is a one-output,
high-voltage supply. It can only be connected to channel
5 or 6 on the ASRU Card. Connect the supply to the
highest numbered module with channel 5 or 6 available.
Use cable E4000-61602 for a 307X system or
E4000-61606 for a 317X or 327X system, or
E2190-61606 for a 79000 system and connect the cables
as shown in
Figure 25 on page 55. 79000 cable
connections are also shown in
Figure 37 on page 75.
Figure 25 6634A/B output connections
Fuse
HP-IB
6634A
Channel 5
OR
Channel 6
Connect one set of wires only.
Unused wires should be tied out
of the way.
20-pin
connector
ASRU card of higher
numbered module
DUT_PS6.wpg
1 - GRN
4 - BLK/RED
3 - BRN/RED
2 - WHT
5 - BLU
8 - RED/BLK
7 - ORN/RED
6 - WHT