Agilent Technologies 81134A Manual de servicio Pagina 46

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 104
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 45
SCPI Commands Reference SOURce Commands
46 Agilent 81133A/81134A Pulse Generator Programming Guide, March 2007
PM[1|2][?] OFF|ON
Sets/reads jitter
modulation
:SENSitivity 25ps|250ps
Sets jitter modulation
sensitivity
:VOLTage
[0|1|2][:LEVel]
[:IMMediate]
[:AMPLitude][?] Numeric [uV|mV|V]
|MIN|MAX
Sets/reads channel
amplitude
:OFFSet[?] Numeric [uV|mV|V]
|MIN|MAX
Sets/reads channel
offset
:HIGH[?] Numeric [uV|mV|V]
|MIN|MAX
Sets/reads channel
high-level
:LOW[?] Numeric [uV|mV|V]
|MIN|MAX
Sets/reads channel low-
level
:TERM[?] Numeric [uV|mV|V]
Sets/reads termination
voltage
[1|2]:LIMit
[:AMPLitude]?
Reads channel
amplitude limit
:OFFSet?
Reads channel offset
limit
:HIGH?
Reads channel high-level
limit
:LOW?
Reads channel low-level
limit
:STATe[?] ON|OFF|1|0
Sets/reads limited
output mode on and off
Command Parameter Description
Vista de pagina 45
1 2 ... 41 42 43 44 45 46 47 48 49 50 51 ... 103 104

Comentarios a estos manuales

Sin comentarios