Vista de pagina 266
:DVM Commands 14
Agilent InfiniiVision 2000 X-Series Oscilloscopes Programmer's Guide 267
:DVM:FREQuency
(see page 790)
Query Syntax
:DVM:FREQuency?
The :DVM:FREQuency? query returns the displayed 5- digit frequency value
that is displayed below the main DVM value.
Return Format
<freq_value><NL>
<freq_value> ::= floating-point number in NR3 format
See Also ":DVM:SOURce" on page 269
":DVM:ENABle" on page 266
":DVM:MODE" on page 268
":DVM:CURRent" on page 265