Agilent Technologies 2000 X-Series Manual de servicio Pagina 657

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 930
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 656
:WAVeform Commands 30
Agilent InfiniiVision 2000 X-Series Oscilloscopes Programmer's Guide 657
:WAVeform:XINCrement
(see page 790)
Query Syntax
:WAVeform:XINCrement?
The :WAVeform:XINCrement? query returns the x- increment value for the
currently specified source. This value is the time difference between
consecutive data points in seconds.
Return Format
<value><NL>
<value> ::= x-increment in the current preamble in 64-bit
floating point NR3 format
See Also "Introduction to :WAVeform Commands" on page 629
":WAVeform:PREamble" on page 644
Example Code "Example Code" on page 645
Vista de pagina 656
1 2 ... 652 653 654 655 656 657 658 659 660 661 662 ... 929 930

Comentarios a estos manuales

Sin comentarios