Command Reference
List/Sweep subsystem ([:SOURce])
Chapter 4 255
:LIST:DWELl
Supported All
[:SOURce]:LIST:DWELl <val>{,<val>}
[:SOURce]:LIST:DWELl?
This command sets the dwell time for the current list sweep points.
The variable <val> is measured in units of seconds with a 0.001 resolution.
NOTE The dwell time (<val>) does not begin until the signal generator has
settled for the current frequency and/or amplitude change. When the
signal generator has settled, a trigger signal is transmitted through the
rear panel SOURCE SETTLED OUTPUT connector.
*RST
Ν/Α
Range 0.001
60
Key Entry N/A
Remarks Dwell time is used when IMMediate is the trigger source. Refer to
“:LIST:TRIGger:SOURce” on page 259 for the trigger setting.
The dwell time is the amount of time the sweep is guaranteed to pause
after setting the frequency and/or power for the current point.
The setting enabled by this command is not affected by signal
generator power-on, preset, or *RST.
:LIST:DWELl:POINts
Supported All
[:SOURce]:LIST:DWELl:POINts?
This command queries the signal generator for the number of dwell points in the current
list sweep file.
*RST Ν/Α
Range Ν/Α
Key Entry N/A
Remarks N/A
Vista de pagina 268