Command Reference
Phase Modulation subsystem ([:SOURce])
Chapter 4276
:PM[1]|2:SOURce
Supported PSG-A Series
[:SOURce]:PM[1]|2:SOURce INT[1]|INT2|EXT1|EXT2
[:SOURce]:PM[1]|2:SOURce?
This command sets the source to generate the phase modulation.
INT This choice selects internal source 1 or 2 to provide an ac-coupled signal.
EXT This choice selects the EXT 1 INPUT or the EXT 2 INPUT connector to
provide an externally applied signal that can be ac- or dc-coupled.
*RST INT
Remarks The externally applied, ac-coupled input signal is tested for a voltage
level and a display annunciator will report a high or low condition if
that voltage is >
±
3% of 1 V
p
.
:PM[1]|2:STATe
Supported PSG-A Series
[:SOURce]:PM[1]|2:STATe ON|OFF|1|0
[:SOURce]:PM[1]|2:STATe?
This command enables or disables the phase modulation for the selected path.
*RST 0
Key Entry
ΦM Off On
Remarks The RF carrier is modulated when you set the signal generator’s
modulation state to ON, see :MODulation[:STATe]” on page 189 for
more information.
Whenever phase modulation is enabled, the
Φ
M annunciator is turned
on in the display
The two paths for phase modulation can be simultaneously enabled.
Refer to “:PM[1]|2...” on page 269 for more information.
Choices INT[1] INT2 EXT1 EXT2
Key Entry
Internal 1Internal 2Ext1Ext2
Choices ON OFF 1 0
Vista de pagina 289