Chapter 5: Troubleshooting
How to Use the Power Fault LEDs
93
in each group indicating the type of failure and the lower two LEDs indicating the source of the failure.
If a shutdown occurs, the table below shows how to decode the upper two LEDs (LEDs 1 and 2) in each
group. Remember these are the LEDs that specify the type of failure that occured. The fault types are
described below the table.
The following table then shows how to decode the bottom two LEDs in each group (LEDs 3 and 4).
Remember that these LEDs specify the source of the failure.
The fault source refers to the input channel of the corresponding sequencer. Below is a listing of the
inputs for each sequencer.
Sequencer 1
Sequencer 2
Fault Type LED1 LED2
Sequence On On
Reset On Off
Command Off On
External Off Off
Fault Source LED3 LED4
1On On
2On Off
3Off On
4 Off Off
Input Supply
1+12V Bulk
2+5 V
3 +3.3 V
4 +2.5 V
Input Supply
1 +1.8V
2 +2.25 V
3 +1.6 V
4 +1.2 V