Agilent Technologies InfiniiVision 3000 DSO-X 3054A Manual de servicio Pagina 191

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 970
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 190
:ACQuire Commands 7
Agilent InfiniiVision 3000 X-Series Oscilloscopes Programmer's Guide 191
:ACQuire:MODE
(see page 860)
Command Syntax
:ACQuire:MODE <mode>
<mode> ::= {RTIMe | SEGMented}
The :ACQuire:MODE command sets the acquisition mode of the
oscilloscope.
The :ACQuire:MODE RTIMe command sets the oscilloscope in real time
mode.
The :ACQuire:MODE SEGMented command sets the oscilloscope in
segmented memory mode.
Query Syntax
:ACQuire:MODE?
The :ACQuire:MODE? query returns the acquisition mode of the
oscilloscope.
Return Format
<mode_argument><NL>
<mode_argument> ::= {RTIM | SEGM}
See Also "Introduction to :ACQuire Commands" on page 187
":ACQuire:TYPE" on page 199
NOTE
The obsolete command ACQuire:TYPE:REALtime is functionally equivalent to sending
ACQuire:MODE RTIMe; TYPE NORMal.
Vista de pagina 190
1 2 ... 186 187 188 189 190 191 192 193 194 195 196 ... 969 970

Comentarios a estos manuales

Sin comentarios