:WAVeform Commands 29
Agilent InfiniiVision 3000 X-Series Oscilloscopes Programmer's Guide 723
The :WAVeform:POINts:MODE? query returns the current points mode.
Setting the points mode will affect what data is transferred. See the
discussion above.
Return Format
<points_mode><NL>
<points_mode> ::= {NORMal | MAXimum | RAW}
See Also "Introduction to :WAVeform Commands" on page 709
":WAVeform:DATA" on page 717
":ACQuire:POINts" on page 192
":WAVeform:VIEW" on page 736
":WAVeform:PREamble" on page 724
":WAVeform:POINts" on page 720
":TIMebase:MODE" on page 631
":ACQuire:TYPE" on page 199
":ACQuire:COUNt" on page 190