Chapter 9 253
Custom Digital Modulation
Using the Real Time I/Q Baseband Generator
Creating User-Defined Custom Modulation
This section teaches you how to perform the following tasks:
“Selecting Data” on page 253
“Configuring the Filter” on page 253
“Selecting a Symbol Rate” on page 253
“Selecting the Modulation Type” on page 253
“Configuring the Burst Rise and Fall Parameters” on page 254
Activating Differential Data Encoding” on page 254
“Generating the Waveform” on page 254
“Configuring the RF Output” on page 254
Selecting Data
1. Press
Preset.
2. Press
Mode > Custom > Real Time I/Q Base Band > Data > FIX4.
3. Press
1010 > Enter > Return.
Configuring the Filter
1. Press
Filter > Select > Gaussian.
2. Press
Filter BbT.
3. Press
.45 > Enter > Return.
Selecting a Symbol Rate
1. Press
Symbol Rate.
2. Press
25 > ksps > Return.
Selecting the Modulation Type
Press
Modulation Type > Select > QAM > 32QAM > Return.
For information on user-defined I/Q mapping, see “User-Defined I/Q Maps” on page 136. For
information on user-defined FSK modulation, see “User-Defined FSK Modulation” on
page 140.