Chapter 1 13
Signal Generator Overview
Front Panel Overview
used to clock the DATA and SYMBOL SYNC signals.
The maximum clock rate is 50 MHz. The damage levels are > +8 and <
−4 V.
This female BNC connector is provided on signal generators with Option 001 or 002. On
signal generators with Option 1EM, this input is relocated to a rear panel SMB connector.
31. DATA (Input Connector)
The TTL/CMOS compatible DATA connector accepts an externally supplied data input for
digital modulation applications. The expected input is a TTL or CMOS signal where a CMOS
high is equivalent to a data 1 and a CMOS low is equivalent to a data 0.
The maximum input data rate is 50 Mb/s.The data must be valid on the DATA CLOCK falling
edges. The damage levels are > +8 and <
−4 V.
This female BNC connector is provided on signal generators with Option 001 or 002. On
signal generators with Option 1EM, this input is relocated to a rear panel SMB connector.
32. Q (Input Connector)
This connector accepts an externally supplied, analog, quadrature-phase component of I/Q
modulation. The signal level is = 0.5 V
rms
for a calibrated output level. The input
impedance is 50
Ω. The damage level is 1 V
rms
.
If you configure your signal generator with Option 1EM, this input is relocated to the rear
panel.
33. I (Input Connector)
This connector accepts an externally supplied, analog, in-phase component of I/Q modulation.
The signal level is = 0.5 V
rms
for a calibrated output level. The input impedance is 50Ω.
The damage level is 1 V
rms
.
If you configure your signal generator with Option 1EM, this input is relocated to the rear
panel.