W-CDMA Uplink Digital Modulation for Receiver Test
Understanding the PRACH
off for that particular relative power. Table 15-1 shows the beta values and their respective
ratios.
When betas are used, the control and data relative powers are calculated using the following
formula:
Relative power = 20 Log (beta/15)
According to the 3GPP standards, at any instant in time, one of the betas for either the control
Table 15-1 Control and Data Part Betas
Beta Values for
Control and Data
Beta
Amplitude/Voltage
Ratios
15 1
14 14/15
13 13/15
12 12/15
11 11/15
10 10/15
99/15
88/15
77/15
66/15
55/15
44/15
33/15
22/15
11/15
0
Off
a
a.
40 dB for the ESG relative power levels