406 Chapter 15
W-CDMA Uplink Digital Modulation for Receiver Test
DPCH
Configuring the E4440A for Viewing the DPCCH/DPDCH Output
This procedure demonstrates a feature of the PSA that enables you to view the ESG output
signal on the E4440A display. Figure 15-38 shows the occupied bandwidth of the W-CDMA
signal.
1. Preset the signal analyzer.
2. Select the W-CDMA mode.
Press
Mode > W-CDMA.
3. Select the mobile setup.
Press
Mode Setup > Radio > Device BTS MS to MS.
4. Set the center frequency.
Press
Frequency Channel > Center Freq > 1.95 > GHz.
5. Display the signal’s bandwidth.
Press
Measure > Occupied BW.
Figure 15-38 Displayed ESG Signal
Vista de pagina 421