142 Agilent InfiniiVision 6000 Series Oscilloscopes Programmer's Guide
5 Commands by Subsystem
See Also "Introduction to Common (*) Commands" on page 128
Example Code
' RESET - This command puts the oscilloscope into a known state.
' This statement is very important for programs to work as expected.
' Most of the following initialization commands are initialized by
' *RST. It is not necessary to reinitialize them unless the default
' setting is not suitable for your application.
myScope.WriteString "*RST" ' Reset the oscilloscope to the defaults.
Example program from the start: "VISA COM Example in Visual Basic" on
page 824
Slope Positive
HF Reject and noise reject Off
Holdoff 60 ns
External probe attenuation AutoProbe (if AutoProbe is connected),
otherwise 1.0:1
External Units Volts
External Impedance 1 M Ohm
Trigger Menu