286 Agilent InfiniiVision 6000 Series Oscilloscopes Programmer's Guide
5 Commands by Subsystem
:FUNCtion:RANGe
(see page 798)
Command Syntax
:FUNCtion:RANGe <range>
<range> ::= the full-scale vertical axis value in NR3 format.
The :FUNCtion:RANGe command defines the full- scale vertical axis for the
selected function.
Query Syntax
:FUNCtion:RANGe?
The :FUNCtion:RANGe? query returns the current full- scale range value for
the selected function.
Return Format
<range><NL>
<range> ::= the full-scale vertical axis value in NR3 format.
The range for ADD, SUBT, MULT is 8E-6 to 800E+3.
The range for the INTegrate function is 8E- 9 to 400E+3 (depends on sweep
speed).
The range for the DIFFerentiate function is 80E- 3 to 8.0E12 (depends on
sweep speed).
The range for the FFT (Fast Fourier Transform) function is 8 to 800 dBV.
See Also "Introduction to :FUNCtion Commands" on page 278
":FUNCtion:SCALe" on page 288