574 Agilent InfiniiVision 6000 Series Oscilloscopes Programmer's Guide
5 Commands by Subsystem
:TRIGger:LIN:SOURce
(see page 798)
Command Syntax
:TRIGger:LIN:SOURce <source>
<source> ::= {CHANnel<n> | EXTernal} for the DSO models
<source> ::= {CHANnel<n> | DIGital0,..,DIGital15} for the MSO models
<n>::={1|2|3|4}forthefour channel oscilloscope models
<n> ::= {1 | 2} for the two channel oscilloscope models
The :TRIGger:LIN:SOURce command sets the source for the LIN signal.
Query Syntax
:TRIGger:LIN:SOURce?
The :TRIGger:LIN:SOURce? query returns the current source for the LIN
signal.
Return Format
<source><NL>
See Also "Introduction to :TRIGger Commands" on page 479
":TRIGger:MODE" on page 485
":TRIGger:LIN:TRIGger" on page 577
":TRIGger:LIN:SIGNal:DEFinition" on page 752