268 Agilent InfiniiVision 6000 Series Oscilloscopes Programmer's Guide
5 Commands by Subsystem
:EXTernal:BWLimit
(see page 798)
Command Syntax
:EXTernal:BWLimit <bwlimit>
<bwlimit> ::= {0 | OFF}
The :EXTernal:BWLimit command is provided for product compatibility.
The only legal value is 0 or OFF. Use the :TRIGger:HFReject command to
limit bandwidth on the external trigger input.
Query Syntax
:EXTernal:BWLimit?
The :EXTernal:BWLimit? query returns the current setting of the low-pass
filter (always 0).
Return Format
<bwlimit><NL>
<bwlimit> ::= 0
See Also "Introduction to :EXTernal Trigger Commands" on page 266
"Introduction to :TRIGger Commands" on page 479
":TRIGger:HFReject" on page 483