680 Appendix D
Softkey Functions
Calibration Menu
(Continued)
ECal
Orientation
Port 2
Selects port 2.
Port B Selects port B as port 2.
:SENS{1-16}:CORR:COLL:ECAL:PATH 2,2
Port C
Selects port C as port 2.
:SENS{1-16}:CORR:COLL:ECAL:PATH 2,3
Port D
Selects port D as port 2.
:SENS{1-16}:CORR:COLL:ECAL:PATH 2,4
Return
Returns to the softkey display screen one level higher.
Port 3 Selects port 3.
Port A Selects port A as port 3.
:SENS{1-16}:CORR:COLL:ECAL:PATH 3,1
Port B
Selects port B as port 3.
:SENS{1-16}:CORR:COLL:ECAL:PATH 3,2
Port C
Selects port C as port 3.
:SENS{1-16}:CORR:COLL:ECAL:PATH 3,3
Port D
Selects port D as port 3.
:SENS{1-16}:CORR:COLL:ECAL:PATH 3,4
Return
Returns to the softkey display screen one level higher.
Port 4 Selects port 4.
Port A Selects port A as port 4.
:SENS{1-16}:CORR:COLL:ECAL:PATH 4,1
Port B
Selects port B as port 4.
:SENS{1-16}:CORR:COLL:ECAL:PATH 4,2
Port C
Selects port C as port 4.
:SENS{1-16}:CORR:COLL:ECAL:PATH 4,3
Port D
Selects port D as port 4.
:SENS{1-16}:CORR:COLL:ECAL:PATH 4,4
Return
Returns to the softkey display screen one level higher.
Return Returns to the softkey display screen one level higher.
Clear Displays the softkey that clears the calibration coefficient except for the scalar-mixer calibration coefficient.
OK Clears all the calibration coefficient.
:SENS{1-16}:CORR:CLE
Cancel
Returns to the softkey display screen one level higher.
Property Enables or disables the display of calibration property. When
enabled, calibration status information between test ports will be
displayed in a matrix format in the lower-right corner of the
channel window.
:SENS{1-16}:CORR:PROP
Cal Kit
Displays softkeys for selecting calibration kits. Up to twenty calibration kits may be defined. Calibration kits
85033E, 85033D, 85052D, 85032F, 85032B, 85036B/E, 85031B, 85050C/D, 85052C and 85038A/F/M are
pre-defined with default settings.
85033E Selects calibration kit 85033E.
:SENS{1-16}:CORR:COLL:CKIT 1
85033D
Selects calibration kit 85033D.
:SENS{1-16}:CORR:COLL:CKIT 2
85052D
Selects calibration kit 85052D.
:SENS{1-16}:CORR:COLL:CKIT 3
85032F
Selects calibration kit 85032F.
:SENS{1-16}:CORR:COLL:CKIT 4
85032B
Selects calibration kit 85032B.
:SENS{1-16}:CORR:COLL:CKIT 5
85036B/E
Selects calibration kit 85036B/E.
:SENS{1-16}:CORR:COLL:CKIT 6
85031B
Selects calibration kit 85031B.
:SENS{1-16}:CORR:COLL:CKIT 7
85050C/D
Selects calibration kit 85050C/D.
:SENS{1-16}:CORR:COLL:CKIT 8
85052C
Selects calibration kit 85052C.
:SENS{1-16}:CORR:COLL:CKIT 9
85038A/F/M
Selects calibration kit 85038A/F/M.
:SENS{1-16}:CORR:COLL:CKIT 10
User
Selects calibration kit User.
:SENS{1-16}:CORR:COLL:CKIT 11
:
:
User Selects calibration kit User.
:SENS{1-16}:CORR:COLL:CKIT 20
Cancel
Returns to the softkey display screen one level higher.
Key Operation Function SCPI Command